Property Value/Assessment Test Standards & Remarks Temperature Range Max service temperature +150˚C, +85˚C for tape EU 5666 Tested acc. to EN 14706 & EN 14707 Min service temperature -50˚C Thermal Conductivity Tubes λ 40˚C ≤ 0.042 W/(m·K) [36.92+0.125⋅ ϑm + 0.0008⋅(ϑm -30)2 ]/1000 EU 5666 Tested acc. to BS 874 Part 2 1986, EN 12667 & EN ISO 8497 Sheets λ 40˚C ≤ 0.045 W/(m·K) [39.92+0.125⋅ ϑm + 0.0008⋅(ϑm -30)2 ]/1000 Water Vapour Diffusion Resistance Tubes μ ≥ 4000 EU 5666 Tested acc.to EN 12086 & EN 13469 Sheet μ ≥ 3000 Fire Performance Reaction to fire Class 1 Euroclass tubes & sheets D-s3, d0 & DL -S3,d0 UL94 GB 5904 & EU5666 Tested acc. to BS476 Part 7: 1997 Classified acc. to EN 13501-1 Tested acc. to EN 13823 EN ISO 11925-2 Other fire class UL approved V-0 Lloyds register material having low flame spread characteristics UL:EU 5837 Lloyd R: EU 6136 UL tested acc. to UL94 IEC 60695 & Can/ CSA-C.22.2. No.0.17, UL 746C. Lloyds Register: Tested acc. to BS 476 Part 7 Practical fire behaviour Self-extinguishing, doesn‘t drip, doesn‘t spread flames Other technical features Dimensions & tolerances In accordance with EN 14304, table 1 EU 5316 Tested acc. to EN 822, EN 823 & EN 13467 UV resistance Good Health aspects Dust & fibre free Storage & shelf life Tape & self-adhesive sheets 1 year Stored in dry clean rooms at normal relative humidity (50% to 70%) and ambient temperature (0˚C - 35˚C ) Resistance to: Building materials: Very good, Chemicals: Consult product test list Ozone: Very good, UV: Very good Environmental aspects ODP zero, GWP zero EU 5197 Material type Synthetic EPDM rubber based foam. Colour Black Applications Thermal insulation of pipes, vessels and ducts for solar panels (including outdoors), motor vehicles, hot gas lines, steam and dual temperature lines. Special features Fulfills DIN 1988, resistant to UV radiation. Safety and environment Type III Environmental Product Declaration (EPD): Declaration number EPD-ARM-20150108-IBB1-DE, institut bauen und umwelt e.V (IBU). Assembly The ArmaFlex application guide should be consulted before use. Remarks Declaration Of Performance (DOP) is available in accordance with Article 7(3) of regulation (EU) No 305/2011 Flexible closed cell elastomeric insulation, based on synthetic EPDM rubber, specifically suitable for installations that work at high temperatures. TECHNICAL DATA 105